ICM X-ray site X 225

FEATURES

UNITS

C2254

C2257

D2258

Output voltage range

kV

70 to 225

70 to 225

70 to 225

Output voltage selection step

kV

1

1

1

Tube current range

mA

1 to 7

1 to 7

1 to 8

Tube current at full output

mA

4

7

8

Tube current selection step

mA

0.1

0.1

0.1

Maximum useful angle of X-ray beam

(¡ã)

360 x (2x20)

360 x (2x20)

60 x 40

Dimensions of optical focal spot

mm

ø 5 x 0.8

ø 5 x 0.8

2.5 x 2.5

Inherent filtration

mm

2.5 (Al) + 0.4 (Ni)

2.5 (Al) + 0.4 (Ni)

2.5 (Al) + 0.4 (Ni)

Carrousel of internal diaphragms with lead cap

-

no

no

yes (4+1)

Working cycle at 40¡ãC ambient temp.

%

100

100

100

Operating temperature range

¡ãC

-25 to +70

-25 to +70

-25 to +70

Storage temperature range

¡ãC

-40 to +80

-40 to +80

-40 to +80

SF6 insulation pressure at 20¡ãC

kg/cm²

5.0

5.0

5.0

Cooling fan supply voltage

VDC

24

24

24

Weatherproof level

-

IP65

IP65

IP65

Penetration into steel at max. power (FFD= 700mm/Film D7pb/D=1.5/T=20 min)

mm Fe

39

44

49

Guard rings

 

no

yes

yes

Position of interconnection socket

choice

Axial/Radial

Axial/Radial

Axial/Radial

Number of telescopic centring device (FFD= 700mm)

-

 

3

1

Maximum leakage dose at 1 m

mSv/h

10

10

10

Microcontroller HT measurement circuit (kV and mA)

-

yes

yes

yes

Overall dimensions

mm

248 x 697

ø 346 x 771

ø 346 x 771

Total weight without guard rings

kg

28

28

28

 
¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­¡­